Customization: | Available |
---|---|
Theory: | Pressure Steam |
Type: | Pressure Steam Sterilization Equipments |
Still deciding? Get samples of US$ 2000/pcs
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
JC series dean sampling vehlde is used for sampling raw or assistant matefial of medicament and preparation (except germfree preparation). Our sampling vehlde reaches to ten thousand level of cleanness In accordance with GMP standard. Besides, electric components comply with GB1497-85 (electric safety standard) and GB-19l(packing standard).
Method of use:
♦Move dean samping vehlde to the ptace needing sampling. Rx it and connect it to power supply. Turn power supply on and turn fan on.
♦Regulate voltage to right range (usuaBy220V); put sampling barrel in It after dean sampling vehicle works for 15min.
♦Take samping barrel away after sampling. Tum off fan and shut off power suppty. Move sampling vehide to original place.
SPECIFICATIONS FOR CLEAN SAMPLING VEHICLE
Model | JC-900 | JC-1200 |
Nomral working concition | temperature 5ºC-40ºC | |
Relative humidity | <80% | |
Atmospheric pressure | 86-106KPa | |
Appearance | Samping vehice box body is made from stainkess steel or steel plate. The decoraltive curtain is smooth, vertical and not damaged. |
|
Trudde | flexible and reliable | |
Ikxnhatbn | Average lumination can not be less then 86-106KPa | |
Purifyiig efficiency | ten thousand or hundred thousand level | |
Average wind speed | 0.4±20%(adjustable) | |
Nose | not more than 63db(A) | |
Vtration | X Y, ZVibration range is not more than 3pm | |
Ctnension of workhg aea(Wl xDl xHl) | 730 x 630 x 950mm | 1030 x 630 x 950mm |
Overal dhiensionfW x Dx H) | 885X690X 1910mm | 1185x690x1910mm |
Power | AC220V/50HZ | |
Mcx power (W) | 400W | 800W |
Weight | 150Kg | 300Kg |
Materid | steel plate vannish /stainless steel |